Zero sequence impedance of underground cables pdf

To illustrate the operation of the impedance measurement and especially the importance of selecting a cor. The zero sequence compensation factor k0 for solid and crossbonded cables is. If a 3 phase to ground fault occurs at bus 5 find the fault mva. The methodology analyzes conventional power signals in the frequency domain to monitor the condition of a power cable. However, when long transmission overhead lines or underground cables are present in the system, the effects of the charging current caused by the shunt capacitance need to be considered. Cyme power engineering software and solutions power cable. Aug 20, 2017 usually the zero sequence impedance can be assumed as 3 times the positive sequence impedance value as a practice for initial approximation the three currents of zero sequence system, equal in magnitude and direction, are opposed by an impedance that is determined by the loops formed by the three cable cores and returned by the metallic sheaths and earth in parallel. However, this is not true for underground cables, where the zero sequence impedance may be nonlinear with respect to distance 1. The cymcap additional modules allow performing several analyses of interest for cables installations like evaluating the magnetic flux density at any point on or above the ground of an underground cable installation, determining the positive and zero sequence impedances and admittances for all the cables present in an installation, performing shortcircuit cable ratings, determining the. Aug 06, 2020 positive and negative sequence impedance is dependent on the impedance of the line from the sending to the receiving end. One important finding of this work is that the zero sequence impedance is not necessarily proportional to the cable length. The above are valid as positive sequence impedance for a cable.

State of the art analysis of online fault location on ac. Similarly, zerosequence impedance is defined as the. The cable sheath or shield grounding method has a major impact on the zero sequence impedance of underground cables. The resistance of the tape shield underground cable can be expressed by s i d r 7653.

Calculation of the zero phase sequence impedance, however, is considerably more complicated, involving not only the permeability of the steel pipe, which depends upon the zero phase sequence current, but. Protection of highvoltage ac cables ieee conference. Positive and zero sequence impedance of cable voltage. Unfortunately, the calculation of zero sequence is more difficult. The zero sequence compensation factor k0 for solid and. If the local compensation coils are accurately dimensioned, the series impedance is. Skm software help desk zero sequence impedance in cables. The power surge impedance loading is calculated only for the lumped section. Three single cables in plastic duct, directburied in a triangular configuration, 90c conductor temperature, 20c ambient temperature, earth rho of 90ccmwatt, 100% load factor, 36 inch depth of burial, and shields. Estimating zerosequence impedance of threeterminal. Zp is the impedance matrix that relates voltage drops across phases to line currents example 2. In this dissertation, we present an improved method for computing the zero sequence impedance. For an accurate calculation of the fault current, it is necessary to know the zero sequence impedance of the underground pipetype cables. Calculating intermediate faults in underground cables schweitzer.

Understanding how the underground cable grounding method affects the series sequence impedances is very fundamental to underground cable protection. Draining the capacitive current that passes through the insulation. Pdf fault detection in transmission line using matlab. Zero sequence impedance of specially bonded screen systems.

The equations are well documented in ieee standards but the southwire power cable manual has a good summary, too. Due to the earth fault of a conductor, the corresponding phaseearth impedance is. Earth faults in extensive cable networks iea lund university. Sequence models and impedances phase domain models are essential when unbalanced operation is of interest. Master thesis in electric power systems and high voltage. The shunt capacitance of adjacent underground cables can be up to 30 to 40 times higher than overhead lines. Understanding how the underground cable grounding method affects the series. Automated transmission line impedance calculation project. Zero sequence impedance measurements on three cables enclosed in a pipe with pipe. Positive sequence and zero sequence impedance tests on twowinding transformers.

The positive sequence impedance test is hvlvn, that is, the hv winding is supplied with the lv winding phase terminals joined together, that is, shortcircuited and connected to neutral. With a saturated earth fault the zero sequence voltage can reach the full value of the phaseneutral point voltage. The same test may be done for the zero sequence impedance if the. This paper focus on the problem of locating singlephase faults in mixed distribution electric systems, with overhead lines and underground cables, using. This is different for zero sequence impedance wherein current flows through the conductor and return through the ground or cable sheath. It is done by creating a model in pscad, which is validated by a set of measurements made on a 60kv cable owned by nyfors as. The parameters of the model were tested in order to see which had in.

Undergroundsubmarine cable protection using a negative. Engineering data for copper and aluminum conductor electrical. Table 6 14 triplexed cable direct burial two circuits 29 table 6 15 three conductor cable underground ducts one circuit, one cable in duct bank 30 table 6 16 three conductor cable underground ducts three circuits, three cables in duct bank 31 table 6 17 three conductor cable underground ducts six circuits, six cables in duct bank 31. Final results when all the input data is entered, the results automatically will be displayed. Zero sequence impedance considers all return in the neutral only. Estimation of zerosequence impedance of undergrounds. The zero sequence voltage at the fault point, v f0, can be calculated from terminal g and h as. To overcome the complexity of manual iterative calculations.

The sequence impedance current calculation of overhead lines is well known and introduced in textbooks 4. Imp0010 code of practice for underground cable ratings. For zero sequence impedance per phase of single cir cuit overhead transmission line with overhead ground wire. Zero sequence impedance, medium voltage cable supply. The electrical differences between the underground cable and transmission line can be. Underground cable, phase impedance matrix, sequence impedance matrix, matlab. Patel, student member, ieee, and piero triverio, member, ieee abstractthe availability of accurate and broadband models for underground and submarine cable systems is of paramount importance for the correct prediction of electromagnetic transients in. Phase conductor spacing decreases x 0 phase conductor spacing unlikely to vary in service. Charging current must be considered when setting the phase elements, to avoid a relay misoperation. Zero sequence mutual impedance for underground cables. Engineering data for copper and aluminum conductor. General calculations excerpt from prysmians wire and.

Underground transmission cables have significantly different. Since calculating series impedance for underground cables is not as simple as in the case of overhead lines, the paper proposes a methodology. Zero sequence mutual impedance for underground cables i have been searching for the zero sequence mutual impedance ideally positive, negative and zero sequence gives the zero sequence data based on how the cable. Calculating series sequence impedance for underground cables is not as simple as calculating the series impedance of overhead lines 3.

Computation of zerosequence impedance of underground. One such component is the power cable, which is the primary focus of this research. Since calculating series impedance for underground cables is not as simple as in the case of overhead lines, the paper proposes a methodology to obtain an estimation of zero sequence impedance of underground cables starting from previous singlefaults occurred in the system, in which an electric arc occurred at the fault location. Z s 2 4 z 0 0 0 0 z 1 0 0 0 z 2 3 5 3 in addition, since e th is representing the generators voltage at the transmission, it can be considered to be balanced, and therefore can be written in the sequence domain as. General calculations excerpt from prysmians wire and cable. A method for measuring underground cable constants under. The following calculator computes the resistance, inductance, inductive reactance, capacitance, charging current, and surge impedance for medium voltage shielded power cables.

An usual value for zero sequence impedance of overhead lines is three times the positive sequence impedance 4 but the zero sequence impedance of the cable is often difficult to be determined. The need to connect it to earth at least at one point along the route. The zero sequence impedance is used when calculating the lineground fault magnitude. Computation of zerosequence impedance of underground three. The cable measurements shall include dc resistance, positive, negative and zero sequence impedances, and shall be expressed at a reference temperature of 20deg c. In the case of pipetype cables or cables in magnetic conduit, zero sequence impedance is not constant and depends on the current flowing through the cable. Pdf estimation of zerosequence impedance of undergrounds. Sequence impedance matrix this method is used when the zero and positive sequence impedances of the feeder are required in the analysis. The cable ratings section is split into two main sections. Estimation of zerosequence impedance of undergrounds cables. Recently, we proposed the momso method for extracting the series impedance of power cables while accounting for skin and proximity effect in the conductors.

The resistance of the concentric neutral underground cable. Protection challenges for north americas first combined. In denmark, as a leading country, the entire 150 kv and. Castro, estimation of zero sequence impedance of undergrounds cables for singlephase fault location in distribution systems with electric arc.

The sequence impedance matrix is calculated by assuming phase rotation of ryb by using z zpnzh. Negative sequence component directional elements provide excellent fault resistance. The paper deals with the sequence impedances positive negative and zero sequences of high and extrahighvoltage land singlecore insulated cables. This calculator provides a good estimate based on industry standard calculation methods and cable manufacturing data. Apr 25, 2016 abstracthighvoltage underground ac cables have significantly different electrical characteristics than overhead transmission lines. This will have a strong influence on the zero sequence impedance and therefore lower the accuracy. Charging current in long lines and highvoltage cables. Sequence impedances of land singlecore insulated cables mdpi. Impedance of cable systems including skin, proximity, and ground return effects utkarsh r. To estimate the zero sequence impedance of line 2, the zero sequence network during a single or double linetoground fault is shown in fig. It acts as the second electrode of the capacitor formed by the cable.

Bus code impedance zpq line charging pq zpq ypq2 3 4 0. Distributed compensation increases the shunt impedance of underground cables so that the influence of the series impedance decreases. The series inductance of underground an cable is typically 50 percent lower than an over head conductor due to the close spacing of conductors. Derivation of theoretical formulas of sequence currents on. However, this is not true for underground cables, where the zero sequence impedance may be nonlinear with respect to distance along the cable. The positive or negative phase sequence impedance of a pipetype cable may be calculated by conventional formulas, suitably modified to include the effect of magnetic properties of the pipe. Effect of transmission line running adjacent to the. Computation of sequence impedances for 220kv underground. The zero sequence parameters of underground cables, and by that the earth fault behaviour, depend on the cables properties as well as the cable installation. The phase sequence impedance of pipetype cables ieee. In balanced studies and, as a good approximation, in fault studies sequence models are useful. Protection of mixed overhead and underground cable lines. Apr 06, 2006 highvoltage underground ac cables have significantly different electrical characteristics than overhead transmission lines. In common with other electrical equipment, the use of cable is not recommended on systems where the ratio of the zero to positive sequence reactance of the system at the point of cable application lies between 1 and 40 since excessively high voltages.

Collation studies of sequence impedances for underground. Calculating intermediate faults in underground cables. Highvoltage underground ac cables have significantly different electrical characteristics than overhead transmission lines. The zero sequence impedance of three underground cables is not the same as the positive sequence impedance. This project we work on the one wave method for the calculation of the underground terminal or two terminal impedance based method. Online thevenin parameter tracking using synchrophasor data. The sequence impedance matrix can be developed using one of the two following methods. Sequence impedance an overview sciencedirect topics. Zero sequence impedance, medium voltage cable supply 7anoter4 electrical 17 apr 20 04.

Underground power cables high voltage underground cables 2 2 circuits 3000m 3x1x2000mm2 e. The values for r, x, b and g are shown in three different sections, each section corresponding to distributed, lumped or total, and per unit values, respectively. This thesis investigates a unique methodology that allows online monitoring of an underground power cable. Case study of 400kv underground cable the physical geometrical data of 400kv underground cable is given in the table shown below 6. Consult the cable manufacturer for insulation thicknesses. Mutual impedance between two underground conductors. Because an underground cable has a zero sequence series impedance.

Z1 is the positive sequence impedance of the line and z0 is the zero sequence impedance of the line in addition, if i n is equal to iphx, the result is exactly the same as indicated by equation 8. Since calculating series impedance for underground cables is not as simple as in the case of overhead lines, the paper proposes a methodology to obtain an estimation of zero sequence impedance of. Estimation of zerosequence impedance of undergrounds cables for singlephase fault location in distribution systems with electric arc september 2009 doi. To obtain the zerosequence impedance, a singlephase voltage at the power frequency is applied to the bonded three phases of one end of the cable circuit, to. Energies free fulltext sequence impedances of land single. An online monitoring and fault location methodology. Several papers have been published on this and the use of carsons equations as a means to calculate the zero sequence impedance is an accepted approach. Calculating series sequence impedance for underground. As soon as a new underground installation is realised, terna can decide to perform a.